Preoperative Evaluations: The Very Last Chance To Identify a Problem With a Pacemaker or Implanted Cardioverter-Defibrillator

References 

  1. Boriani G, Biffi M, Martignani C. Uneventful right ventricular perforation with displacement of a pacing lead into the left thorax. J Cardiothorac Vasc Anesth. 2008;22:423–425
  2. Preisman S, Cheng DC. Life-threatening ventricular dysrhythmias with inadvertent asynchronous temporary pacing after cardiac surgery. Anesthesiology. 1999;91:880–883
  3. Maisel WH, Moynahan M, Zuckerman BD, et al. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports. JAMA. 2006;295:1901–1906
  4. Samain E, Schauveliege F, Henry C, et al. Outcome in patients with a cardiac pacemaker undergoing noncardiac surgery. Anesthesiology. 2001;95:A142;(abstr)
  5. Rozner MA, Nguyen AD, Roberson JC. Inadequate pacemaker follow-up detected at the preanesthetic visit. Anesthesiology. 2002;96:A1071;(abstr)
  6. Guidant. Urgent medical device safety information and corrective action (Vitality ICD) (Published 7/22/2006). http://www.bostonscientific.com/templatedata/imports/HTML/PPR/files/physician/vit_he_renewal.pdfAccessed January 1, 2007
  7. Medtronic. Important patient management information (Sigma series pacemakers) (Published 11/2005). http://www.medtronic.com/crmLetter.htmlAccessed October 19, 2007
  8. Guidant: Urgent medical device safety information and corrective action (Contak Renewal [3,4,RF] ICD [magnet switch]). Published 6/23/2005. Available at: http://www.bostonscientific.com/templatedata/imports/HTML/PPR/ppr/support/current_advisories.pdf. Accessed April 11, 2008
  9. Medtronic. Urgent medical device information: Sprint Fidelis lead patient management recommendations (Published 10/15/2007). http://www.medtronic.com/fidelis/physician-letter.htmlAccessed October 19, 2007
  10. Hasdemir C, Shah N, Rao AP, et al. Analysis of troponin I levels after spontaneous implantable cardioverter defibrillator shocks. J Cardiovasc Electrophysiol. 2002;13:144–150
  11. Practice advisory for the perioperative management of patients with cardiac rhythm management devices: Pacemakers and implantable cardioverter-defibrillators: A report by the American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Cardiac Rhythm Management Devices. Anesthesiology. 2005;103:186–198
  12. Fleisher , Lee A, Beckman JA, et al. ACC/AHA 2007 guidelines on perioperative cardiovascular evaluation and care for noncardiac surgery (A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (writing committee to revise the 2002 guidelines on perioperative cardiovascular evaluation for noncardiac surgery). Published 9/27/2007). http://circ.ahajournals.org/cgi/content/abstract/CIRCULATIONAHA.107.185699v1Accessed January 8, 2008