Journal of Cardiothoracic and Vascular Anesthesia
Volume 22, Issue 5 , Pages 688-692 , October 2008

The Effects of Vasodilation on Cardiac Output Measured by PiCCO

  • Koichi Yamashita, MD, PhD

      Affiliations

    • Department of Anesthesiology and Critical Care Medicine, Kochi Medical School, Nankoku, Japan
    • Corresponding Author InformationAddress reprint requests to Koichi Yamashita, MD, PhD, Department of Anesthesiology and Critical Care Medicine, Kochi Medical School, Okohasu, Oko-cho, Nankoku-shi, Kochi, 783-8505, Japan
  • ,
  • Tomoki Nishiyama, MD, PhD

      Affiliations

    • Department of Anesthesiology, The University of Tokyo, Tokyo, Japan
  • ,
  • Takeshi Yokoyama, DDS, PhD

      Affiliations

    • Department of Anesthesiology and Critical Care Medicine, Kochi Medical School, Nankoku, Japan
  • ,
  • Hidehiro Abe, MD

      Affiliations

    • Department of Anesthesiology and Critical Care Medicine, Kochi Medical School, Nankoku, Japan
  • ,
  • Masanobu Manabe, MD, PhD

      Affiliations

    • Department of Anesthesiology and Critical Care Medicine, Kochi Medical School, Nankoku, Japan

References 

  1. Linton NWF, Linton RAF. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth. 2001;86:486–496
  2. Van Lieshout JJ, Wesseling KH. Editorial (II. Continuous cardiac output by pulse contour analysis?). Br J Anaesth. 2001;86:467–468
  3. Jansen JRC, Schreuder JJ, Mulier JP, et al. A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth. 2001;87:212–222
  4. Rödig G, Prasser C, Keyl C, et al. Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgery patients. Br J Anaesth. 1999;82:525–530
  5. Pittman J, Bar-Yosef S, SumPing J, et al. Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement. Crit Care Med. 2005;33:2015–2021
  6. Bein B, Meybohm P, Cavus E, et al. The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg. 2007;105:107–113
  7. Halvorsen PS, Sokolov A, Cvancarova M, et al. Continuous cardiac output during off-pump coronary artery bypass grafting: Pulse-contour analysis vs pulmonary artery thermodilution. Br J Anaesth. 2007;99:484-482
  8. Chakravarthy M, Patil TA, Jayaprakash K, et al. Comparison of stimultaneous estimation of cardiac output by four techniques in patients undergoing off-pump coronary artery surgery—A prospective observational study. Ann Card Anaesth. 2007;10:121–126
  9. Goedje O, Hoke K, Goetz AE, et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med. 2002;15:52–58
  10. Jones CJ, Sugawara M, Kondoh Y, et al. Compression and expansion wavefront travel in canine ascending aortic flow: Wave intensity analysis. Heart Vessels. 2002;16:91–98
  11. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;8476:307–310
  12. Chen L, Seaber AV, Urbaniak JR. Vasodilator action of prostaglangin E1 on microcirculation of rat cremaster muscle. Microsurgery. 1990;11:204–208
  13. Miyabe M, Fukuda T, Saito S, et al. Effect of intravenous prostaglandin E1 on pig veesel diameters and intracranial pressure in rabbits. Acta Anaesthesiol Scand. 2001;45:1271–1275
  14. Goto F, Otani E, Fujita T. Antihypaertensive activity and metabolic rate of prostaglandin E2 in surgical patients under general anesthesia. Prostaglandins Leukot Med. 1985;18:359–366
  15. Irlbeck M, Forst H, Briegel J, et al. Continuous measurement of cardiac output with pulse contour analysis. Anaesthesist. 1995;44:493–500
  16. Critchley LAH, Critchley JAJH. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit. 1999;15:85–91
  17. Rödig G, Prasser C, Keyl C, et al. Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgery patients. Br J Anaesth. 1999;82:525–530
  18. Schmid ER, Schmidlin D, Tornic M, et al. Continuous thermodilution cardiac output: Clinical validation against a reference technique of known accuracy. Intensive Care Med. 1990;25:166–172
  19. Jansen JR, Schreuder JJ, Settels JJ, et al. An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med. 1990;16:422–425

PII: S1053-0770(08)00098-0

doi: 10.1053/j.jvca.2008.04.007

Journal of Cardiothoracic and Vascular Anesthesia
Volume 22, Issue 5 , Pages 688-692 , October 2008