Hemodynamic Stability During Biventricular Pacing After Cardiopulmonary Bypass

Mathew E. Spotnitz, MS, Daniel Y. Wang, MD, T. Alexander Quinn, PhD, Marc E. Richmond, MD, Alexander Rusanov, MD§Corresponding Author Informationemail address, Taylor Johnston, MD§, Bin Cheng, PhD, Santos E. Cabreriza, MBA, Henry M. Spotnitz, MD

published online 20 July 2010.
Corrected Proof

Objective

To assess the stability of cardiac output, mean arterial pressure, and systemic vascular resistance during biventricular pacing (BiVP) optimization.

Design

Substudy analysis of data collected as part of a randomized controlled study examining the effects of optimized temporary BiVP after cardiopulmonary bypass (CPB).

Setting

A single-center study at a university-affiliated tertiary care hospital.

Participants

Cardiac surgery patients at risk of left ventricular failure after CPB.

Interventions

BiVP was optimized immediately after CPB. Atrioventricular delay (7 unique settings) was optimized first, followed by the left ventricular pacing site (3 unique settings) and then the interventricular delay (9 unique settings). Each setting was tested twice for 10 seconds each time. Vasoactive medication and fluid infusion rates were held constant.

Measurements and Main Results

Aortic flow velocity and radial artery pressure were digitized, recorded, and averaged over single respiratory cycles. Least squares and linear regression/Wilcoxon analyses were applied to the first 7 patients studied. Subsequently, curvilinear analysis was applied to 15 patients. Changes in mean arterial pressure and systemic vascular resistance were statistically insignificant or too small to be meaningful by least squares analysis. During interventricular synchrony optimization, cardiac output and mean arterial pressure decreased (mean changes −5.7% and −2.5%, respectively; with standard errors 2.3% and 1.5%, respectively), whereas SVR increased (mean change 3.1% with standard error 3.4%). Only the change in cardiac output was statistically significant (p = 0.043). Curvilinear fits to data for 15 patients demonstrated progressive hemodynamic stability over the total testing period.

Conclusion

BiVP optimization may be done safely in patients after CPB. With continuous monitoring of mean arterial pressure and cardiac output, the procedure results in no harmful hemodynamic perturbation.

 Department of Surgery, Columbia University Medical Center, New York, NY, USA

 Department of Medicine, Columbia University Medical Center, New York, NY, USA

 Department of Pediatrics, Columbia University Medical Center, New York, NY, USA

§ Department of Anesthesiology, Columbia University Medical Center, New York, NY

 Department of Physiology, Anatomy and Genetics, University of Oxford, Oxford, UK, UK;

 Department of Biostatistics, Mailman School of Public Health, New York, NY

Corresponding Author InformationAddress reprint requests to Henry M. Spotnitz, MD, Department of Surgery, Columbia University Medical Center, 622 West 168th Street, VC 10-1010, New York, NY 10032-3784

 Supported in part by a USHPHS grant HL-080152 (NHLBI), “Biventricular Pacing after Cardiopulmonary Bypass.” D.Y.W. is supported by an NIH Training Grant, 5 T32 HL007854-13. M.E.S. was supported by a Dean's Summer Research Fellowship from the Columbia University College of Physicians and Surgeons. A.R. is supported by an NIH Training Grant, 5 T32 GM008464-17. H.M.S. is the George H. Humphreys, II, Professor of Surgery.

PII: S1053-0770(10)00192-8

doi:10.1053/j.jvca.2010.04.021